Sea-Bird routinely supplies these third party instruments integrated with
Sea-Bird instruments, and supported by Sea-Bird software. The Sea-Bird part
numbers for the third party sensors do not include the necessary interface
cables or mounting hardware for mounting on Sea-Bird instruments. Order the
appropriate Interface option (part number that includes 'Int') as well as the
sensor. Click the third party manufacturer in the list below
or scroll through the page to find the desired product.
(Where applicable, links are provided to application notes
describing integration of third party sensors with Sea-Bird instruments and to
Acrobat .pdf drawings for cables.)
Note: We do not publish prices on the website. Please contact Sea-Bird (seabird@seabird.com
or 425-643-9866) for pricing.
Should I order third party sensors from Sea-Bird, or deal directly with the sensors' manufacturers?
Third Party Instrument Configuration:
Links to other pages:
See Application
Note 11General: PAR Light Sensors, 24253 Biospherical QSP-2300L Quantum
Scalar (4 pi) PAR (log amp) sensor,
2000 m 24254 24255 24256 BIOInt-1a PAR & CTD/Carousel integration, cable, &
mount kit (CTD with Standard connectors) BIOInt-1b PAR &
CTD/Carousel integration, cable, &
mount kit (CTD with Wet-pluggable connectors) BIOInt-2a PAR
& CTD integration, cable, & mount kit (CTD with Standard connectors)
BIOInt-2b PAR & CTD integration, cable, & mount kit (CTD
with Wet-pluggable connectors) 24257
Application Note 11QSP-L:
Calculating Calibration Coefficients for Biospherical PAR Sensor with
Built-In Log Amplifier,
Application Note 11QSP-PD:
Calculating Calibration Coefficients for Biospherical PAR Sensor without
Built-in Log Amplifier,
Application Note 11S: Using
Biospherical Surface PAR Light Sensor with SBE 11plus Deck Unit, and
Application Note 47: Using
Biospherical Surface PAR Light Sensor with SBE 33 or SBE 36 Deck Unit.
Biospherical QCP-2300L
Quantum (cosine) PAR (log
amp) sensor,
2000 m
24268 Biospherical QCR-2200 Surface PAR Reference sensor (used with SBE 11plus, SBE 33, or SBE 36)
See Application Note 81:
Entering Calibration Coefficients for D&A Instruments OBS-3+ Optical
Backscatter Sensor. 24311
D&A OBS 3+
Turbidity Sensor,
1500
m titanium housing, two 0-5V outputs -- 0-1000 & 0-4000 NTU. Measures suspended solids & turbidity by optical backscatter
method.
24312 D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-250 & 0-1000 NTU. Measures suspended solids & turbidity by optical backscatter method.
24313 D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-500 & 0-2000 NTU. Measures suspended solids & turbidity by optical backscatter method.
172130 Interface cable, OBS 3+, High & Low range, AG-206 to MCIL-5MP, 1 m (DN 33080)
172131 Interface cable, OBS 3+, Wet-pluggable, High & Low range, MCIL-6FS to MCIL-5MP, 1 m (DN 33081)
172109 Interface cable, OBS 3+, Low range (1X), AG-206 to MCIL-5MP, 1 m (DN 33058)
172111 Interface cable, OBS 3+, Wet-pluggable, Low range (1X), MCIL-6FS to MCIL-5MP, 1 m (DN 33060)
172110 Interface cable, OBS 3+, High range (4X), AG-206 to MCIL-5MP, 1 m (DN 33059)
172112 Interface cable, OBS 3+, Wet-pluggable, High range (4X), MCIL-6FS to MCIL-5MP, 1 m (DN 33061)
50187 Seapoint/OBS 3+ Turbidity/AMT pH sensor mount kit (strap on Seacat/Sealogger housing)
50230 Seapoint/OBS 3+ Turbidity/AMT pH strap on mount for 9plus
50193 Seapoint/OBS 3+ Turbidity/AMT pH sensor mount block (SBE 25 cage mount)
50294 Seapoint/OBS 3+ Turbidity/AMT pH sensor mount block (SBE 19/19plus cage mount)
50266 Seapoint/OBS 3+ Turbidity/AMT pH sensor mount block for Carousel extension stand (1-inch diameter Carousel frame stock)
50285 Seapoint/OBS 3+ Turbidity/AMT pH sensor mount (32C/SC Carousel lower guard)
See Application
Note 11General: PAR Light Sensors and 24080
Application Note 11Licor:
Calculating Calibration Coefficients for Licor Underwater Type SA PAR
Light Sensors without Built-in Log Amplifier.
Li-Cor LI-193-SA PAR sensor (spherical), 350
m
LI-193Int-1a PAR & CTD integration (16/19/25), cable, & mount kit (CTD with Standard connectors)
LI-193Int-1b PAR & CTD integration (16/19/25), cable, & mount kit (CTD with Wet-pluggable connectors)
LI-193Int-2a PAR & CTD/Carousel integration, cable, & mount kit (CTD with Standard connectors)
LI-193Int-2b PAR & CTD/Carousel integration, cable, & mount kit (CTD with Wet-pluggable connectors)
24108 Li-Cor LI-192-SA PAR sensor (flat), 560 m
LI-192Int-1a PAR & CTD integration (16/19), cable, & mount kit (CTD with Standard connectors)
LI-192Int-1b PAR & CTD integration (16/19), cable, & mount kit (CTD with Wet-pluggable connectors)
LI-192Int-1c PAR & CTD integration (SBE 25 cage), cable, & mount kit (CTD with Standard connectors)
LI-192Int-1d PAR & CTD integration (SBE 25 cage), cable, & mount kit (CTD with Wet-pluggable connectors)
LI-192Int-2a PAR & CTD (19/25)/Carousel integration, cable, & mount kit (CTD with Standard connectors)
LI-192Int-2b PAR & CTD (19/25)/Carousel integration, cable, & mount kit (CTD with Wet-pluggable connectors)
See
SBE
Improved Sample Bottles for 5 liter through 12 liter bottle sizes. 70082
70190
70083
70194 70074
70191
70075
70195 70086
70192
70087
70196 70088
70193
70089 70197
Note: Bottles do not include lanyards; order lanyard
materials separately (see
Sample
Bottles & Bottle Spares).
OTE PVC sample bottle, 1.7 liter
See Application Note 48:
Entering Calibration Coefficients for the Seapoint Turbidity Meter, 24187
Application Note 54: Entering
Calibration Coefficients for the Seapoint Fluorometer, and
Application Note 77: Entering
Calibration Coefficients for the Seapoint Ultraviolet Fluorometer.
Seapoint Chlorophyll Fluorometer, 6000
m
24267 Seapoint Rhodamine Fluorometer, 6000 m
24301 Seapoint Ultra Violet (CDOM) Fluorometer, 6000 m
SCFInt-1a Seapoint Fluorometer & CTD integration (19/25 cage) for CTD with Standard connectors, 1x gain (0-150 µg/l Chlorophyll a or Rhodamine, 1500 µg/l CDOM), includes cabling & mounting
SCFInt-1b Seapoint Fluorometer & CTD integration (19/25 cage for CTD with Standard connectors, 3x gain (0-50 µg/l Chlorophyll a or Rhodamine, 500 µg/l CDOM), includes cabling & mounting
SCFInt-1c Seapoint Fluorometer & CTD integration (19/25 cage) for CTD with Standard connectors, 10x gain (0-15 µg/l Chlorophyll a or Rhodamine, 150 µg/l CDOM), includes cabling & mounting
SCFInt-1d Seapoint Fluorometer & CTD integration (19/25 cage) for CTD with Standard connectors, 30x gain (0-5 µg/l Chlorophyll a or Rhodamine, 50 µg/l CDOM), includes cabling & mounting
SCFInt-1e Seapoint Fluorometer & CTD integration (19/25 cage) for CTD with Wet-pluggable connectors, 1x gain (0-150 µg/l Chlorophyll a or Rhodamine, 1500 µg/l CDOM), includes cabling & mounting
SCFInt-1f Seapoint Fluorometer & CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, 3x gain (0-50 µg/l Chlorophyll a or Rhodamine, 500 µg/l CDOM), including cabling & mounting
SCFInt-1g Seapoint Fluorometer & CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, 10x gain (0-15 µg/l Chlorophyll a or Rhodamine, 150 µg/l CDOM), includes cabling & mounting
SCFInt-1h Seapoint Fluorometer & CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, 30x gain (0-5 µg/l Chlorophyll a or Rhodamine, 50 µg/l CDOM), includes cabling & mounting
SCFInt-2a Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 1x gain (0-150 µg/l Chlorophyll a or Rhodamine, 1500 µg/l CDOM), includes cabling & mounting
SCFInt-2b Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 3x gain (0-50 µg/l Chlorophyll a or Rhodamine, 500 µg/l CDOM), includes cabling & mounting
SCFInt-2c Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 10x gain (0-15 µg/l Chlorophyll a or Rhodamine, 150 µg/l CDOM), includes cabling & mounting
SCFInt-2d Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 30x gain (0-5 µg/l Chlorophyll a or Rhodamine, 50 µg/l CDOM), includes cabling & mounting
SCFInt-2e Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (0-150 µg/l Chlorophyll a or Rhodamine, 1500 µg/l CDOM), includes cabling & mounting
SCFInt-2f Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 3x gain (0-50 µg/l Chlorophyll a or Rhodamine, 500 µg/l CDOM), includes cabling & mounting
SCFInt-2g Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (0-15 µg/l Chlorophyll a or Rhodamine, 150 µg/l CDOM), includes cabling & mounting
SCFInt-2h Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 30x gain (0-5 µg/l Chlorophyll a or Rhodamine, 50 µg/l CDOM), includes cabling & mounting
24179 Seapoint Turbidity Meter (STM), 6000 m
STMInt-1a STM & CTD integration (19/25 cage) for CTD with Standard connectors, 1x gain (0- >750 FTU), includes cabling & mounting
STMInt-1b STM & CTD integration (19/25 cage) for CTD with Standard connectors, 5x gain (0-500 FTU), includes cabling & mounting
STMInt-1c STM & CTD integration (19/25 cage) for CTD with Standard connectors, 20x gain (0-125 FTU), includes cabling & mounting
STMInt-1d STM & CTD integration (19/25 cage) for CTD with Standard connectors, 100x gain (0-25 FTU), includes cabling & mounting
STMInt-1e STM & CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, 1x gain (0- >750 FTU), includes cabling & mounting
STMInt-1f STM & CTD integration (19/25 cage) for CTD with Wet-pluggable connectors, 5x gain (0-500 FTU), includes cabling & mounting
STMInt-1g STM & CTD integration (19/25 cage) for CTD with Wet-pluggable connectors, 20x gain (0-125 FTU), includes cabling & mounting
STMInt-1h STM & CTD integration (19/25 cage) for CTD with Wet-pluggable connectors, 100x gain (0-25 FTU), includes cabling & mounting
STMInt-2a STM & CTD integration (strap-on) for CTD with Standard connectors, 1x gain (0- >750 FTU), includes cabling & mounting
STMInt-2b STM & CTD integration (strap-on) for CTD with Standard connectors, 5x gain (0-500 FTU), includes cabling & mounting
STMInt-2c STM & CTD integration (strap-on) for CTD with Standard connectors, 20x gain (0-125 FTU), includes cabling & mounting
STMInt-2d STM & CTD integration (strap-on) for CTD with Standard connectors, 100x gain (0-25 FTU), includes cabling & mounting
STMInt-2e STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 1x gain (0- >750FTU), includes cabling & mounting
STMInt-2f STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 5x gain (0-500 FTU), includes cabling & mounting
STMInt-2g STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 20x gain (0-125 FTU), includes cabling & mounting
STMInt-2h STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 100x gain (0-25 FTU), includes cabling & mounting
50394 3-Cable set of Seapoint gain jumper cables (includes 17972, 17973, & 17974)
171099 Seapoint sensors interface cable (1X gain), 107 cm (DN 32073)
17975 Seapoint gain jumper cable, 20 cm (1X STM, Fluor, or CDOM) (DN 31879)
17974 Seapoint gain jumper cable, 20 cm (5X STM, or 3X Fluor or CDOM) (DN 31878)
17973 Seapoint gain jumper cable, 20 cm (20X STM, or 10X Fluor or CDOM) (DN 31877)
17972 Seapoint gain jumper cable, 20 cm (100X STM, or 30X Fluor or CDOM) (DN 31876)
24204 Benthos PSA-916D Altimeter, 6000 m
916Int-1a PSA-916D & CTD/Carousel integration, cable, & mount kit (CTD with Standard connectors)
916Int-1b PSA-916D & CTD/Carousel integration, cable, & mount kit (CTD with Wet-pluggable connectors)
916Int-2a PSA-916D & CTD integration, cable, & mount kit (CTD with Standard connectors)
916Int-2b PSA-916D & CTD integration, cable, & mount kit (CTD with Wet-pluggable connectors)
See Application Note 63:
Calculating Calibration Coefficients for the Turner SCUFA (I, II, or III)
Fluorometer/OBS and 24248
24263
Application Note 74:
Calculating Calibration Coefficients for Turner Cyclops-7 Fluorometer.
Turner SCUFA II
Chlorophyll & Turbidity sensor, 600 m
SCUFAInt-1a SCUFA/CTD integration (19/25 cage) for CTD with Standard connectors, includes cabling & mounting
SCUFAInt-1b SCUFA/CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, includes cabling & mounting
SCUFAInt-2a SCUFA/CTD integration (strap-on) for CTD with Standard connectors, includes cabling & mounting
SCUFAInt-2b SCUFA/CTD integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting
24265 SCUFA solid secondary calibration standard (2000-901)
24271
Turner CYCLOPS-7 Chlorophyll Fluorometer, 600 m. Order optional flow cap for pumped applications separately.24292 CYCLOPS-7 Flow Through Cap (2100-600)
24291
CYCLOPS-7 solid secondary calibration standard (Chlor/Rhodamine, 2100-900)CYCLOPInt-1a CYCLOPS-7/CTD integration (strap-on) for CTD with Standard connectors, 1x gain (0-500 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1b CYCLOPS-7/CTD integration (strap-on) for CTD with Standard connectors, 10x gain (0-50 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1c CYCLOPS-7/CTD integration (strap-on) for CTD with Standard connectors, 100x gain (0-5 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1d CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (0-500 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1e CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (0-50 µg/l Chlorophyll a), includes cabling & mounting
CYCLOPInt-1f CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 100x gain (0-5 µg/l Chlorophyll a), includes cabling & mounting
Wet Labs Fluorometers
See Application Note 41:
Calculating Calibration Coefficients for the WET Labs WETStar Fluorometer,
Application Note 62: Calculating
Calibration Coefficients for the WET Labs ECO-AFL or ECO-FL Fluorometer, and
Application Note 72: Setting Up WET
Labs ECO-FL Fluorometer with Bio-Wiper.
WET Labs WETStar Chlorophyll fluorometer for pumped applications, 600 m plastic housing, 75 µg/l range24190
24191
WET Labs WETStar Chlorophyll fluorometer for pumped applications, 600 m plastic housing, 150 µg/l range24261 WET Labs WETStar Colored Dissolved Organic Matter (CDOM) Fluorometer for pumped applications, 600 m
WSInt-1a WETStar & CTD Integration (strap-on) for CTD with Standard connectors, includes cabling & mounting
WSInt-1b WETStar & CTD Integration (strap-on) for CTD with Wet-pluggable connectors, includes cabling & mounting
WSInt-2a WETStar & CTD Integration (cage mount) for CTD with Standard connectors, includes cabling & mounting
WSInt-2b WETStar & CTD Integration (cage mount) for CTD with Wet-pluggable connectors, includes cabling & mounting
WSInt-3a WETStar & CTD Integration (32C/SC pod) for CTD with Standard connectors, includes cabling & mounting
WSInt-3b WETStar & CTD Integration (32C/SC pod) for CTD with Wet-pluggable connectors, includes cabling & mounting
24245 WET Labs ECO-FL(RT) Chlorophyll fluorometer, 100 µg/l range, 600 m
24258 WET Labs ECO-FL(RT)D Deep Chlorophyll fluorometer, 100 µg/l range, 6000 m
24270 WET Labs ECO-FLS Chlorophyll fluorometer with bio-wiper™, 300 m, 100 µg/l range
24272 WET Labs ECO-FL-NTU(RT) Chlorophyll & Turbidity sensor, 600 m, 0.02-60 µg/l & 0-25 NTU (other ranges by special order)
24297 WET Labs ECO-FL-NTU(RT) Deep Chlorophyll & Turbidity sensor, 6000 m, 0.02-60 µg/l & 0-25 NTU (other ranges by special order)
24273 WET Labs ECO-FL-NTUS Chlorophyll & Turbidity sensor with bio-wiper™, 300 m, 0.02-60 µg/l & 0-25 NTU (other ranges by special order)
ECOInt-1a ECO & CTD Integration (19/25 cage) for CTD with Standard connectors, includes cabling & mounting
ECOInt-1b ECO & CTD Integration (19/25 cage), for CTD with Wet-pluggable connectors, includes cabling & mounting
ECOInt-2a ECO & CTD Integration (strap-on) for CTD with Standard connectors, includes cabling & mounting
ECOInt-2b ECO & CTD Integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting
ECOInt-3a ECO & CTD Integration (32C/SC pod) for CTD with Standard connectors, includes cabling & mounting
ECOInt-3b ECO & CTD Integration (32C/SC pod), for CTD with Wet-pluggable connectors, includes cabling & mounting
Wet Labs Transmissometers
See Application Note 7: Calculation of Calibration Coefficients for Transmissometers.
WET Labs cs-25-660-p (red) C-STAR transmissometer, 600 m, 25 cm path24183
24209
WET Labs cs-25-532-p (green) C-STAR transmissometer, 600 m, 25 cm path24182
WET Labs cs-10-660-p (red) C-STAR transmissometer, 600 m, 10 cm path24211
WET Labs cs-25-660 (red) C-STAR transmissometer, 6000 m, 25 cm path24176
WET Labs C-STAR flow tube (CSFT), 25 cm (for moored applications)24177
WET Labs C-STAR flow tube (CSFT), 10 cm (for moored applications)24298 WET Labs C-STAR flow tube (CSFTLR-25), 25 cm (Leak Resistant for benchtop applications)
24299 WET Labs C-STAR flow tube (CSFTLR-10), 10 cm (Leak Resistant for benchtop applications)
CSint-1a C-Star & 9plus CTD Integration (strap-on) for CTD with Standard connectors, includes cabling & mounting
CSint-1b C-Star & 9plus CTD Integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting
CSint-2a C-Star & 19/25 CTD Integration (strap-on or cage mount) for CTD with Standard connectors, includes cabling & mounting
CSint-2b C-Star & 19/25 CTD Integration (strap-on or cage mount), for CTD with Wet-pluggable connectors, includes cabling & mounting
CSint-3a C-Star & CTD/Carousel Integration (32C/32SC pod) for CTD with Standard connectors, includes cabling & mounting
CSint-3b C-Star & CTD/Carousel Integration (32C/32SC pod), for CTD with Wet-pluggable connectors, includes cabling & mounting
Wet Labs
Light Scattering Sensors 24259 WET Labs ECO-BBRT
Single-Angle Scattering Meter, 600 m 24260 WET Labs
ECO-BBRTD Deep
Single-Angle Scattering Meter, 6000 m ECOInt-1a ECO & CTD Integration (19/25 cage)
for CTD with Standard connectors, includes cabling &
mounting ECOInt-1b ECO & CTD
Integration (19/25 cage), for CTD with Wet-pluggable connectors, includes
cabling & mounting ECOInt-2a ECO & CTD Integration (strap-on)
for CTD with Standard connectors, includes cabling & mounting
ECOInt-2b
ECO & CTD Integration (strap-on), for CTD with Wet-pluggable
connectors, includes cabling & mounting ECOInt-3a ECO & CTD Integration
(32C/SC pod) for CTD with Standard connectors, includes cabling & mounting
ECOInt-3b ECO & CTD Integration (32C/SC pod),
for CTD with Wet-pluggable connectors, includes cabling & mounting