Sea-Bird Electronics              Products            Support            Software            Sales            Service            Search/Sitemap

Third Party Product Configuration Options

Sea-Bird routinely supplies these third party instruments integrated with Sea-Bird instruments, and supported by Sea-Bird software. The Sea-Bird part numbers for the third party sensors do not include the necessary interface cables or mounting hardware for mounting on Sea-Bird instruments. Order the appropriate Interface option (part number that includes 'Int') as well as the sensor. Click the third party manufacturer in the list below or scroll through the page to find the desired product.
(Where applicable, links are provided to application notes describing integration of third party sensors with Sea-Bird instruments and to Acrobat .pdf drawings for cables.)

Note: We do not publish prices on the website. Please contact Sea-Bird (seabird@seabird.com or 425-643-9866) for pricing.

Should I order third party sensors from Sea-Bird, or deal directly with the sensors' manufacturers?

Third Party Instrument Configuration:

Links to other pages:

 

Biospherical Instruments PAR Sensors

See Application Note 11General: PAR Light Sensors,
Application Note 11QSP-L: Calculating Calibration Coefficients for Biospherical PAR Sensor with Built-In Log Amplifier,
Application Note 11QSP-PD: Calculating Calibration Coefficients for Biospherical PAR Sensor without Built-in Log Amplifier,
Application Note 11S: Using Biospherical Surface PAR Light Sensor with SBE 11plus Deck Unit, and
Application Note 47: Using Biospherical Surface PAR Light Sensor with SBE 33 or SBE 36 Deck Unit.

24253    Biospherical QSP-2300L Quantum Scalar (4 pi) PAR (log amp) sensor, 2000 m

24254    Biospherical QCP-2300L Quantum (cosine) PAR (log amp) sensor, 2000 m

24255    Biospherical QSP-2200 (PD) (4 pi) PAR sensor, 2000 m

24256    Biospherical QCP-2200 (PD) (cosine) PAR sensor, 2000 m

BIOInt-1a   PAR & CTD/Carousel integration, cable, & mount kit (CTD with Standard connectors)

BIOInt-1b   PAR & CTD/Carousel integration, cable, & mount kit (CTD with Wet-pluggable connectors)

BIOInt-2a   PAR & CTD integration, cable, & mount kit (CTD with Standard connectors)

BIOInt-2b   PAR & CTD integration, cable, & mount kit (CTD with Wet-pluggable connectors)

24257    Biospherical QSR-2200 Surface PAR Reference sensor (used with SBE 11plus, SBE 33, or SBE 36)

24268    Biospherical QCR-2200 Surface PAR Reference sensor (used with SBE 11plus, SBE 33, or SBE 36)

D & A Instruments Optical Backscatter Sensor (turbidity)

See Application Note 81: Entering Calibration Coefficients for D&A Instruments OBS-3+ Optical Backscatter Sensor.

24311    D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-1000 & 0-4000 NTU. Measures suspended solids & turbidity by optical backscatter method.

24312    D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-250 & 0-1000 NTU. Measures suspended solids & turbidity by optical backscatter method.

24313    D&A OBS 3+ Turbidity Sensor, 1500 m titanium housing, two 0-5V outputs -- 0-500 & 0-2000 NTU. Measures suspended solids & turbidity by optical backscatter method.

172130   Interface cable, OBS 3+, High & Low range, AG-206 to MCIL-5MP, 1 m (DN 33080)

172131   Interface cable, OBS 3+, Wet-pluggable, High & Low range, MCIL-6FS to MCIL-5MP, 1 m (DN 33081)

172109   Interface cable, OBS 3+, Low range (1X), AG-206 to MCIL-5MP, 1 m (DN 33058)

172111   Interface cable, OBS 3+, Wet-pluggable, Low range (1X), MCIL-6FS to MCIL-5MP, 1 m (DN 33060)

172110   Interface cable, OBS 3+, High range (4X), AG-206 to MCIL-5MP, 1 m (DN 33059)

172112   Interface cable, OBS 3+, Wet-pluggable, High range (4X), MCIL-6FS to MCIL-5MP, 1 m (DN 33061)

50187     Seapoint/OBS 3+ Turbidity/AMT pH sensor mount kit (strap on Seacat/Sealogger housing)

50230     Seapoint/OBS 3+ Turbidity/AMT pH strap on mount for 9plus

50193     Seapoint/OBS 3+ Turbidity/AMT pH sensor mount block (SBE 25 cage mount)

50294     Seapoint/OBS 3+ Turbidity/AMT pH sensor mount block (SBE 19/19plus cage mount)

50266     Seapoint/OBS 3+ Turbidity/AMT pH sensor mount block for Carousel extension stand (1-inch diameter Carousel frame stock)

50285     Seapoint/OBS 3+ Turbidity/AMT pH sensor mount (32C/SC Carousel lower guard)

Li-Cor PAR Sensors

See Application Note 11General: PAR Light Sensors and
Application Note 11Licor: Calculating Calibration Coefficients for Licor Underwater Type SA PAR Light Sensors without Built-in Log Amplifier.

24080    Li-Cor LI-193-SA PAR sensor (spherical), 350 m

LI-193Int-1a   PAR & CTD integration (16/19/25), cable, & mount kit (CTD with Standard connectors)

LI-193Int-1b   PAR & CTD integration (16/19/25), cable, & mount kit (CTD with Wet-pluggable connectors)

LI-193Int-2a   PAR & CTD/Carousel integration, cable, & mount kit (CTD with Standard connectors)

LI-193Int-2b   PAR & CTD/Carousel integration, cable, & mount kit (CTD with Wet-pluggable connectors)

24108    Li-Cor LI-192-SA PAR sensor (flat), 560 m

LI-192Int-1a   PAR & CTD integration (16/19), cable, & mount kit (CTD with Standard connectors)

LI-192Int-1b   PAR & CTD integration (16/19), cable, & mount kit (CTD with Wet-pluggable connectors)

LI-192Int-1c   PAR & CTD integration (SBE 25 cage), cable, & mount kit (CTD with Standard connectors)

LI-192Int-1d   PAR & CTD integration (SBE 25 cage), cable, & mount kit (CTD with Wet-pluggable connectors)

LI-192Int-2a   PAR & CTD (19/25)/Carousel integration, cable, & mount kit (CTD with Standard connectors)

LI-192Int-2b   PAR & CTD (19/25)/Carousel integration, cable, & mount kit (CTD with Wet-pluggable connectors)

Ocean Test Equipment Water Sample Bottles

See SBE Improved Sample Bottles for 5 liter through 12 liter bottle sizes.
Note:
Bottles do not include lanyards; order lanyard materials separately (see Sample Bottles & Bottle Spares).

70082    OTE PVC sample bottle, 1.7 liter

70190    OTE PVC sample bottle, 1.7 liter with external spring

70083    OTE PVC sample bottle, 1.7 liter with reversing thermometer assembly

70194    OTE PVC sample bottle, 1.7 liter with RTA & external spring

70074    OTE PVC sample bottle, 2.5 liter

70191    OTE PVC sample bottle, 2.5 liter with external spring

70075    OTE PVC sample bottle, 2.5 liter with reversing thermometer assembly

70195    OTE PVC sample bottle, 2.5 liter with RTA & external spring

70086    OTE PVC sample bottle, 20 liter

70192    OTE PVC sample bottle, 20 liter with external spring

70087    OTE PVC sample bottle, 20 liter with reversing thermometer assembly

70196    OTE PVC sample bottle, 20 liter with RTA & external spring

70088    OTE PVC sample bottle, 30 liter

70193    OTE PVC sample bottle, 30 liter with external spring

70089    OTE PVC sample bottle, 30 liter with reversing thermometer assembly

70197    OTE PVC sample bottle, 30 liter with RTA & external spring

Seapoint Sensors Fluorometers & Turbidity Sensors

See Application Note 48: Entering Calibration Coefficients for the Seapoint Turbidity Meter, 
Application Note 54: Entering Calibration Coefficients for the Seapoint Fluorometer, and
Application Note 77: Entering Calibration Coefficients for the Seapoint Ultraviolet Fluorometer.

24187    Seapoint Chlorophyll Fluorometer, 6000 m

24267    Seapoint Rhodamine Fluorometer, 6000 m

24301    Seapoint Ultra Violet (CDOM) Fluorometer, 6000 m

SCFInt-1a   Seapoint Fluorometer & CTD integration (19/25 cage) for CTD with Standard connectors, 1x gain (0-150 µg/l Chlorophyll a or Rhodamine, 1500 µg/l CDOM), includes cabling & mounting

SCFInt-1b   Seapoint Fluorometer & CTD integration (19/25 cage for CTD with Standard connectors, 3x gain (0-50 µg/l Chlorophyll a or Rhodamine, 500 µg/l CDOM), includes cabling & mounting

SCFInt-1c   Seapoint Fluorometer & CTD integration (19/25 cage) for CTD with Standard connectors, 10x gain (0-15 µg/l Chlorophyll a or Rhodamine, 150 µg/l CDOM), includes cabling & mounting

SCFInt-1d   Seapoint Fluorometer & CTD integration (19/25 cage) for CTD with Standard connectors, 30x gain (0-5 µg/l Chlorophyll a or Rhodamine, 50 µg/l CDOM), includes cabling & mounting

SCFInt-1e   Seapoint Fluorometer & CTD integration (19/25 cage) for CTD with Wet-pluggable connectors, 1x gain (0-150 µg/l Chlorophyll a or Rhodamine, 1500 µg/l CDOM), includes cabling & mounting

SCFInt-1f   Seapoint Fluorometer & CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, 3x gain (0-50 µg/l Chlorophyll a or Rhodamine, 500 µg/l CDOM), including cabling & mounting

SCFInt-1g   Seapoint Fluorometer & CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, 10x gain (0-15 µg/l Chlorophyll a or Rhodamine, 150 µg/l CDOM), includes cabling & mounting

SCFInt-1h   Seapoint Fluorometer & CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, 30x gain (0-5 µg/l Chlorophyll a or Rhodamine, 50 µg/l CDOM), includes cabling & mounting

SCFInt-2a   Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 1x gain (0-150 µg/l Chlorophyll a or Rhodamine, 1500 µg/l CDOM), includes cabling & mounting

SCFInt-2b   Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 3x gain (0-50 µg/l Chlorophyll a or Rhodamine, 500 µg/l CDOM), includes cabling & mounting

SCFInt-2c   Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 10x gain (0-15 µg/l Chlorophyll a or Rhodamine, 150 µg/l CDOM), includes cabling & mounting

SCFInt-2d   Seapoint Fluorometer & CTD integration (strap-on) for CTD with Standard connectors, 30x gain (0-5 µg/l Chlorophyll a or Rhodamine, 50 µg/l CDOM), includes cabling & mounting

SCFInt-2e   Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (0-150 µg/l Chlorophyll a or Rhodamine, 1500 µg/l CDOM), includes cabling & mounting

SCFInt-2f   Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 3x gain (0-50 µg/l Chlorophyll a or Rhodamine, 500 µg/l CDOM), includes cabling & mounting

SCFInt-2g   Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (0-15 µg/l Chlorophyll a or Rhodamine, 150 µg/l CDOM), includes cabling & mounting

SCFInt-2h  Seapoint Fluorometer & CTD integration (strap-on), for CTD with Wet-pluggable connectors, 30x gain (0-5 µg/l Chlorophyll a or Rhodamine, 50 µg/l CDOM), includes cabling & mounting

24179    Seapoint Turbidity Meter (STM), 6000 m

STMInt-1a   STM & CTD integration (19/25 cage) for CTD with Standard connectors, 1x gain (0- >750 FTU), includes cabling & mounting

STMInt-1b   STM & CTD integration (19/25 cage) for CTD with Standard connectors, 5x gain (0-500 FTU), includes cabling & mounting

STMInt-1c   STM & CTD integration (19/25 cage) for CTD with Standard connectors, 20x gain (0-125 FTU), includes cabling & mounting

STMInt-1d   STM & CTD integration (19/25 cage) for CTD with Standard connectors, 100x gain (0-25 FTU), includes cabling & mounting

STMInt-1e   STM & CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, 1x gain (0- >750 FTU), includes cabling & mounting

STMInt-1f   STM & CTD integration (19/25 cage) for CTD with Wet-pluggable connectors, 5x gain (0-500 FTU), includes cabling & mounting

STMInt-1g   STM & CTD integration (19/25 cage) for CTD with Wet-pluggable connectors, 20x gain (0-125 FTU), includes cabling & mounting

STMInt-1h  STM & CTD integration (19/25 cage) for CTD with Wet-pluggable connectors, 100x gain (0-25 FTU), includes cabling & mounting

STMInt-2a   STM & CTD integration (strap-on) for CTD with Standard connectors, 1x gain (0- >750 FTU), includes cabling & mounting

STMInt-2b   STM & CTD integration (strap-on) for CTD with Standard connectors, 5x gain (0-500 FTU), includes cabling & mounting

STMInt-2c   STM & CTD integration (strap-on) for CTD with Standard connectors, 20x gain (0-125 FTU), includes cabling & mounting

STMInt-2d   STM & CTD integration (strap-on) for CTD with Standard connectors, 100x gain (0-25 FTU), includes cabling & mounting

STMInt-2e   STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 1x gain (0- >750FTU), includes cabling & mounting

STMInt-2f   STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 5x gain (0-500 FTU), includes cabling & mounting

STMInt-2g   STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 20x gain (0-125 FTU), includes cabling & mounting

STMInt-2h  STM & CTD integration (strap-on) for CTD with Wet-pluggable connectors, 100x gain (0-25 FTU), includes cabling & mounting

50394    3-Cable set of Seapoint gain jumper cables (includes 17972, 17973, & 17974)

171099    Seapoint sensors interface cable (1X gain), 107 cm (DN 32073)

17975     Seapoint gain jumper cable, 20 cm (1X STM, Fluor, or CDOM) (DN 31879)

17974     Seapoint gain jumper cable, 20 cm (5X STM, or 3X Fluor or CDOM) (DN 31878)

17973     Seapoint gain jumper cable, 20 cm (20X STM, or 10X Fluor or CDOM) (DN 31877)

17972     Seapoint gain jumper cable, 20 cm (100X STM, or 30X Fluor or CDOM) (DN 31876)

Teledyne Benthos (formerly Datasonics) Altimeters

24204    Benthos PSA-916D Altimeter, 6000 m

916Int-1a   PSA-916D & CTD/Carousel integration, cable, & mount kit (CTD with Standard connectors)

916Int-1b   PSA-916D & CTD/Carousel integration, cable, & mount kit (CTD with Wet-pluggable connectors)

916Int-2a  PSA-916D & CTD integration, cable, & mount kit (CTD with Standard connectors)

916Int-2b  PSA-916D & CTD integration, cable, & mount kit (CTD with Wet-pluggable connectors)

Turner Designs Fluorometer/Turbidity Sensor

See Application Note 63: Calculating Calibration Coefficients for the Turner SCUFA (I, II, or III) Fluorometer/OBS and
Application Note 74: Calculating Calibration Coefficients for Turner Cyclops-7 Fluorometer.

24248    Turner SCUFA II Chlorophyll & Turbidity sensor, 600 m

24263    Turner SCUFA III Rhodamine & Turbidity sensor, 600 m

SCUFAInt-1a   SCUFA/CTD integration (19/25 cage) for CTD with Standard connectors, includes cabling & mounting

SCUFAInt-1b   SCUFA/CTD integration (19/25 cage), for CTD with Wet-pluggable connectors, includes cabling & mounting

SCUFAInt-2a   SCUFA/CTD integration (strap-on) for CTD with Standard connectors, includes cabling & mounting

SCUFAInt-2b   SCUFA/CTD integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting

24265     SCUFA solid secondary calibration standard (2000-901)

24271    Turner CYCLOPS-7 Chlorophyll Fluorometer, 600 m. Order optional flow cap for pumped applications separately.

24292    CYCLOPS-7 Flow Through Cap (2100-600)

24291    CYCLOPS-7 solid secondary calibration standard (Chlor/Rhodamine, 2100-900)

CYCLOPInt-1a   CYCLOPS-7/CTD integration (strap-on) for CTD with Standard connectors, 1x gain (0-500 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1b   CYCLOPS-7/CTD integration (strap-on) for CTD with Standard connectors, 10x gain (0-50 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1c   CYCLOPS-7/CTD integration (strap-on) for CTD with Standard connectors, 100x gain (0-5 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1d   CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 1x gain (0-500 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1e   CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 10x gain (0-50 µg/l Chlorophyll a), includes cabling & mounting

CYCLOPInt-1f   CYCLOPS-7/CTD integration (strap-on), for CTD with Wet-pluggable connectors, 100x gain (0-5 µg/l Chlorophyll a), includes cabling & mounting

WET Labs Fluorometers, Transmissometers, and Light Scattering Sensors

Wet Labs Fluorometers

See Application Note 41: Calculating Calibration Coefficients for the WET Labs WETStar Fluorometer, 
Application Note 62: Calculating Calibration Coefficients for the WET Labs ECO-AFL or ECO-FL Fluorometer, and
Application Note 72: Setting Up WET Labs ECO-FL Fluorometer with Bio-Wiper.

24190    WET Labs WETStar Chlorophyll fluorometer for pumped applications, 600 m plastic housing, 75 µg/l range

24191    WET Labs WETStar Chlorophyll fluorometer for pumped applications, 600 m plastic housing, 150 µg/l range

24261    WET Labs WETStar Colored Dissolved Organic Matter (CDOM) Fluorometer for pumped applications, 600 m

WSInt-1a   WETStar & CTD Integration (strap-on) for CTD with Standard connectors, includes cabling & mounting

WSInt-1b   WETStar & CTD Integration (strap-on) for CTD with Wet-pluggable connectors, includes cabling & mounting

WSInt-2a   WETStar & CTD Integration (cage mount) for CTD with Standard connectors, includes cabling & mounting

WSInt-2b   WETStar & CTD Integration (cage mount) for CTD with Wet-pluggable connectors, includes cabling & mounting

WSInt-3a   WETStar & CTD Integration (32C/SC pod) for CTD with Standard connectors, includes cabling & mounting

WSInt-3b   WETStar & CTD Integration (32C/SC pod) for CTD with Wet-pluggable connectors, includes cabling & mounting

24245    WET Labs ECO-FL(RT) Chlorophyll fluorometer, 100 µg/l range,  600 m

24258    WET Labs ECO-FL(RT)D Deep Chlorophyll fluorometer, 100 µg/l range, 6000 m

24270    WET Labs ECO-FLS Chlorophyll fluorometer with bio-wiper™, 300 m, 100 µg/l range

24272    WET Labs ECO-FL-NTU(RT) Chlorophyll & Turbidity sensor, 600 m, 0.02-60 µg/l & 0-25 NTU (other ranges by special order)

24297    WET Labs ECO-FL-NTU(RT) Deep Chlorophyll & Turbidity sensor, 6000 m, 0.02-60 µg/l & 0-25 NTU (other ranges by special order)

24273    WET Labs ECO-FL-NTUS Chlorophyll & Turbidity sensor with bio-wiper™, 300 m, 0.02-60 µg/l & 0-25 NTU (other ranges by special order)

ECOInt-1a   ECO & CTD Integration (19/25 cage) for CTD with Standard connectors, includes cabling & mounting

ECOInt-1b   ECO & CTD Integration (19/25 cage), for CTD with Wet-pluggable connectors, includes cabling & mounting

ECOInt-2a   ECO & CTD Integration (strap-on) for CTD with Standard connectors, includes cabling & mounting

ECOInt-2b   ECO & CTD Integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting

ECOInt-3a   ECO & CTD Integration (32C/SC pod) for CTD with Standard connectors, includes cabling & mounting

ECOInt-3b   ECO & CTD Integration (32C/SC pod), for CTD with Wet-pluggable connectors, includes cabling & mounting

Wet Labs Transmissometers

See Application Note 7: Calculation of Calibration Coefficients for Transmissometers.

24183    WET Labs cs-25-660-p (red) C-STAR transmissometer, 600 m, 25 cm path

24209    WET Labs cs-25-532-p (green) C-STAR transmissometer, 600 m, 25 cm path

24182    WET Labs cs-10-660-p (red) C-STAR transmissometer, 600 m, 10 cm path

24211    WET Labs cs-25-660 (red) C-STAR transmissometer, 6000 m, 25 cm path

24176    WET Labs C-STAR  flow tube (CSFT), 25 cm (for moored applications)

24177    WET Labs C-STAR flow tube (CSFT), 10 cm (for moored applications)

24298    WET Labs C-STAR  flow tube (CSFTLR-25), 25 cm (Leak Resistant for benchtop applications)

24299    WET Labs C-STAR  flow tube (CSFTLR-10), 10 cm (Leak Resistant for benchtop applications)

CSint-1a   C-Star & 9plus CTD Integration (strap-on) for CTD with Standard connectors, includes cabling & mounting

CSint-1b   C-Star & 9plus CTD Integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting

CSint-2a   C-Star & 19/25 CTD Integration (strap-on or cage mount) for CTD with Standard connectors, includes cabling & mounting

CSint-2b   C-Star & 19/25 CTD Integration (strap-on or cage mount), for CTD with Wet-pluggable connectors, includes cabling & mounting

CSint-3a   C-Star & CTD/Carousel Integration (32C/32SC pod) for CTD with Standard connectors, includes cabling & mounting

CSint-3b   C-Star & CTD/Carousel Integration (32C/32SC pod), for CTD with Wet-pluggable connectors, includes cabling & mounting

Wet Labs Light Scattering Sensors

24259    WET Labs ECO-BBRT Single-Angle Scattering Meter, 600 m

24260    WET Labs ECO-BBRTD Deep Single-Angle Scattering Meter, 6000 m

ECOInt-1a   ECO & CTD Integration (19/25 cage) for CTD with Standard connectors, includes cabling & mounting

ECOInt-1b   ECO & CTD Integration (19/25 cage), for CTD with Wet-pluggable connectors, includes cabling & mounting

ECOInt-2a   ECO & CTD Integration (strap-on) for CTD with Standard connectors, includes cabling & mounting

ECOInt-2b   ECO & CTD Integration (strap-on), for CTD with Wet-pluggable connectors, includes cabling & mounting

ECOInt-3a   ECO & CTD Integration (32C/SC pod) for CTD with Standard connectors, includes cabling & mounting

ECOInt-3b   ECO & CTD Integration (32C/SC pod), for CTD with Wet-pluggable connectors, includes cabling & mounting

[HRule Image]

Last modified: 06-Apr-2007

Sea-Bird Home     Phone: 425-643-9866     Fax: 425-643-9954     E-mail: seabird@seabird.com