Brochure/specifications
Manual
Note: We do not publish prices on the website. Please contact Sea-Bird (seabird@seabird.com
or 425-643-9866) for pricing.
| Part # | Description | Notes |
| 11plus V2 | DECK UNIT for 911plus CTD - Version 2 (V2) includes IEEE-488 & RS-232 interfaces, water sampler modem channel, NMEA 0183 GPS interface, A/D input channel for Surface PAR reference sensor, ASCII serial data output port, CTD pressure signal output, audible bottom contact alarm, audio tape interface, 115/230 VAC (switchable) input power, AC power cord, serial data cable, NMEA test cable, remote output cable, rack mount kit, SEASOFT software, & complete documentation. | For photos of standard shipment,
click here.
9plus provides real-time data when
controlled with 11plus V2 Deck Unit. 11plus V2 provides power, decodes
data stream, passes data to computer, & allows user control of water sampler.
Notes: |
|
SBE 11plus V2 Modem Option |
||
| 11p-1a | DELETE for Credit -- 300 baud modem module for water sampler control | Standard 9plus / 11plus system can provide real-time control for an SBE 32 or 32C Carousel Water Sampler or G.O. 1016 water sampler. With real-time control, bottles are closed by command from ship, typically while monitoring real-time CTD data. Water sampler modem not required for use without a water sampler unless option 9p-11a or 11b Serial Data Uplink is specified. |
| SBE 11plus V2 Accessories | ||
![]() 11plus V2 Back Panel -- many of remaining parts relate to connections to back panel |
||
| 17556 | Deck Unit signal input cable (from slip rings to Deck Unit), 10m (DN 31371) | Pigtail connects Sea Cable on 11plus V2 to slip rings. |
| 80915 | Test cable, 11/33/36 deck unit to 9/32/PDIM, 10 m (DN 31314) | Connects Sea Cable on 11plus V2 to 9plus CTD for testing. Shorter cable PN 80591 (2.4 m) is included with standard shipment; this is spare. |
| 32000 | Technical Manual (spare), SBE 911plus CTD system | Includes 9plus CTD manual & 11plus V2 Deck Unit manual. These manuals are customized for your application, & include instrument configuration, calibration sheets, & schematics specific to your instrument. Note that electronic version of customized manuals are available on CD-ROM that accompanies shipment; see links at top of page for generic manuals. |
| 17015 | AC Power cord (US Standard), 2 m | One of these (as applicable) as included with standard shipment; this is spare. |
| 17824 | AC power cord, European plug, 2 m | |
| 801237 | Cable, shielded, SBE 14 to SBE 11plus V2, 100 m (DN 32433) | Connects Remote Out on 11plus
V2 to
SBE 14 (Remote Depth
Readout). SBE 14 is powered & controlled by 11plus V2 & provides visual
display of 9plus depth, pressure, or altitude (if altimeter installed
on 9plus) as well as alarm that sounds upon reaching user-programmed
pressure or altimeter limits. Extra RS-232 serial port is not needed (11plus V2 requires 1 serial port or GPIB parallel port for data, &, if applicable 1 serial port for communication with SBE 32 or 32C Carousel Water Sampler), since SBE 14 connects directly to 11plus V2 instead of to computer. |
| 801429 | Remote Data Output Test Cable, DB-9S to MS3106A, 1.8 m (DN 32799) | Connects Remote Out on 11plus V2 to computer to set up Remote Output interface. Cable is included with standard shipment; this is spare. |
| 801367 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 15 m (DN 32704) | Connects Surface PAR on 11plus V2 to Biospherical surface PAR sensor. See Third Party portion of price list to order Surface PAR sensor. |
| 801368 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 30 m (DN 32704) | |
| 801375 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 40 m (DN 32704) | |
| 801369 | Cable, QSR/QCR-2200 SPAR to Deck Unit, 50 m (DN 32704) | |
| 50086 | 2-pin connector, deck unit seacable input | Connects to Sea Cable on 11plus V2. Included with standard shipment; this is spare. |
| 30017 | SBE 11plus rack mounting kit (spare) | For mounting 11plus V2 in standard rack. Included with standard shipment; this is spare. See document 67059. |
| 801422 | NMEA Test Cable, DB-9S to MS3106A, SBE 11p/33/36/45, 1.8 m (DN 32786) | Connects NMEA on 11plus V2 to computer
simulating NMEA input for testing 11plus V2 NMEA interface. Included with standard
shipment; this is spare. NMEA simulation program, NMEATest, is part of SEASOFT software, & is installed when you install SBE Data Processing. |
|
SBE 11plus V2 Spares |
||
| 80673 | 11plus modem board | |
| 40934C | Receiver Board | |
| 40937C | Digital Board | |
| 20033 | Mallory SC628MN alarm buzzer | Alarm sounds based on data from bottom contact switch &/or altimeter connected to 9plus, &/or minimum/maximum user-input pressure values. |
| 22002 | Primary power supply (Power One HTAA-16W-A) | |
| 80811 | NMEA interface board (V1 deck units only) | |
| 80040 | LED display board | 11plus V2 front panel provides numeric display of frequency & voltage data via thumbwheel switch & 8-digit LED readout. |
| 20018 | Cooling Fan | |
| 80586 | 11plus sea cable power supply | |
| 19006 | Thumbwheel switch | 11plus V2 front panel provides numeric display of frequency & voltage data via thumbwheel switch & 8-digit LED readout. |
| 171886 | RS-232 serial cable, DB-25P to DB-9S, 3 m | Spare cable from computer to SBE 11 Interface (RS-232) or Modem Channel on 11plus V2 back panel. See 171886 for pinouts. |
| 171890 | RS-232 serial data uplink cable, DB-9P to DB-9S, 3 m | Spare cable from computer to 9600 Baud
Uplink on 11plus V2 back panel. See
171890 for pinouts.
If 9p-11b (19200 baud) selected, continuous transmission rate may not exceed 9600 baud (960 bytes/second). Therefore, serial data output instrument must transmit at 19200 baud in burst mode (transmissions separated by intervals with no data transmission, resulting in average rate of 960 bytes/second). *Note: 300 baud modem in 9plus & 11plus has been standard since early 2005. For older instruments, it was optional. |
Product configuration options listing for all products
![]()
Last modified: 06 Apr 2007
Sea-Bird Home Phone: 425-643-9866 Fax: 425-643-9954 E-mail: seabird@seabird.com