Brochure/specifications
Manual
Reference Sheet
Note: We do not publish prices on the website. Please contact Sea-Bird (seabird@seabird.com
or 425-643-9866) for pricing.
| Part # | Description | Notes | |
| 16plus-IM | SEACATplus Conductivity & Temperature Recorder with Inductive Modem. Includes 600 m plastic housing, 8 MB memory, AF24173 Anti-Foulant Devices, SEASOFT software, & complete documentation. Specify: housing (depth), auxiliary channel, mooring clamp wire size selections (mount clamp wire size to match O.D. of wire jacket). |
For photos of standard shipment,
click here. Communicating with 1 or more 16plus-IMs requires use of Sea-Bird Surface Inductive Modem (SIM), which provides serial interface (RS-232 or RS-485) between user’s computer & up to 100 IM instruments coupled to single cable. Purchase SIM & optional Inductive Cable Coupler (ICC) separately; see separate listing. See SBE 37-IM or 37-IMP MicroCAT for instrument without auxiliary sensor input capability. |
|
|
SBE 16plus-IM Housing (depth) Selections -- MUST SELECT ONE |
|||
| 16PIM-1a | 600 m plastic housing |
|
|
| 16PIM-1b | 7000 m titanium housing | ||
| 16PIM-1c | 10,500 m titanium housing | ||
| SBE 16plus-IM Mooring Wire Guide Size Selections (specify clamp to match O.D. of the mooring wire jacket) -- MUST SELECT ONE | |||
| 16PIM-2a | Wire guide & mounting clamp for 1/4 in. diameter mooring wire |
Cable fits loosely through IM coupling core / wire
guide, & is clamped only at mounting clamp. This avoids putting
through tension on end cap, which could pull off end cap. See document
67142 for mechanical details. Thread for clamping to mooring cable:
|
|
| 16PIM-2b | Wire guide & mounting clamp for 5/16 in. diameter mooring wire | ||
| 16PIM-2c | Wire guide & mounting clamp for 3/8 in. diameter mooring wire | ||
| 16PIM-2d | Wire guide & mounting clamp for 1/2 in. diameter mooring wire | ||
| 16PIM-2e | Wire guide & mounting clamp for 6 mm diameter mooring wire | ||
| 16PIM-2f | Wire guide & mounting clamp for 8 mm diameter mooring wire | ||
| 16PIM-2g | Wire guide & mounting clamp for 10 mm diameter mooring wire | ||
| 16PIM-2h | Wire guide & mounting clamp for 12 mm diameter mooring wire | ||
| 16PIM-2i | Wire guide & mounting clamp for 16 mm (5/8 in.) diameter mooring wire | ||
|
SBE 16plus-IM Auxiliary Input Channel Configuration Selections -- MUST SELECT ONE |
|||
| 16PIM-3a | 4 differential A/D channels (0 - 5 volt input range) |
Note: 16PIM-3a, -3b, & -3c do not include auxiliary sensors, mounts, or interface cables.
|
|
| 16PIM-3b | 3 differential A/D channels, 1 log amp channel (for PAR) | ||
| 16PIM-3c | 4 differential A/D channels & 1 RS-232 data input channel for SBE 38, SBE 50, or GTD | ||
| SBE 16plus-IM Strain Gauge Pressure Sensor Options | |||
| 16PIM-4a | 20 m strain gauge pressure sensor |
Pressure sensor is installed in connector end cap, & is not field replaceable / swappable.
While highest pressure rating gives you most flexibility in using 16plus-IM, it is at expense of
accuracy & resolution. It is advantageous to use lowest range
pressure sensor compatible with your intended maximum operating
depth, because accuracy & resolution are proportional to
pressure sensor's full scale range. For example, comparing 2000 &
7000 m sensors --
|
|
| 16PIM-4b | 100 m strain gauge pressure sensor | ||
| 16PIM-4c | 350 m strain gauge pressure sensor | ||
| 16PIM-4s | 600 m strain gauge pressure sensor | ||
| 16PIM-4d | 1000 m strain gauge pressure sensor | ||
| 16PIM-4e | 2000 m strain gauge pressure sensor | ||
| 16PIM-4f | 3500 m strain gauge pressure sensor | ||
| 16PIM-4g | 7000 m strain gauge pressure sensor | ||
|
SBE 16plus-IM Digiquartz Pressure Sensor Options (substitutes for strain gauge option) |
|||
| 16PIM-4h | 45 psia Digiquartz with temperature compensation |
Digiquartz pressure sensors provide better accuracy
(0.02% of full scale range vs 0.1% of full scale range) &
resolution (Digiquartz resolution dependent on user-programmable
integration time) than strain gauge pressure sensors. See SBE 16plus-IM Strain Gauge Pressure Sensor Options
above for photo of pressure sensor port. Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 16plus-IM, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 psia (1400 m) & 6000 psia (4200 m) sensors --
|
|
| 16PIM-4i | 100 psia Digiquartz with temperature compensation | ||
| 16PIM-4j | 200 psia Digiquartz with temperature compensation | ||
| 16PIM-4k | 300 psia Digiquartz with temperature compensation | ||
| 16PIM-4l | 400 psia Digiquartz with temperature compensation | ||
| 16PIM-4m | 1000 psia Digiquartz with temperature compensation | ||
| 16PIM-4n | 2000 psia Digiquartz with temperature compensation | ||
| 16PIM-4o | 3000 psia Digiquartz with temperature compensation | ||
| 16PIM-4p | 6000 psia Digiquartz with temperature compensation | ||
| 16PIM-4q | 10,000 psia Digiquartz with temperature compensation | ||
| 16PIM-4r | 15,000 psia Digiquartz with temperature compensation | ||
| SBE 16plus-IM Submersible Pump Options | |||
| 16PIM-5a | Add SBE 5M pump for sensor flushing (includes cable & mount) |
Pump bulkhead connector on 16plus-IM is standard, so pump can be added in the field without requiring any modifications to 16plus-IM. These all include pump, pump mount, & pump interface cable. 16PIM-5c & 5d include pump cable compatible with wet-pluggable bulkhead connectors on 16plus-IM & on pump. Pump (SBE 5M or 5T) is titanium, regardless of 16plus-IM housing option, & is rated for 10,500 m. |
|
| 16PIM-5b | Add SBE 5T pump for sensor flushing (includes cable & mount) | ||
| 16PIM-5c | Add SBE 5M pump with Wet-pluggable MCBH connectors for sensor flushing (includes cable & mount. Requires Option 16PIM-6_) | ||
| 16PIM-5d | Add SBE 5T pump with Wet-pluggable MCBH connectors for sensor flushing (includes cable & mount. Requires Option 16PIM-6_) | ||
|
SBE 16plus-IM Wet-Pluggable Connector Options |
|||
| 16PIM-6a | Substitute Wet-pluggable (MCBH) connectors for Standard (XSG) connectors on SEACAT pump & A/D channel connections |
Wet-pluggable connectors may be mated in wet
conditions. Their pins do not need to be dried before mating. By
design, water on connector pins is forced out as connector
is mated. However, they must not be mated or un-mated while
submerged. Wet-pluggable connectors have a non-conducting guide pin
to assist pin alignment & require less force to mate, making them
easier to mate reliably under dark or cold conditions, compared to
our standard (Impulse XSG/RMG) connectors. Like standard connectors,
wet-pluggables need proper lubrication & require care during use
to avoid trapping water in sockets.
|
|
| 16PIM-6b | Substitute Wet-pluggable (MCBH) connectors for Standard (XSG) connectors on SEACAT pump, A/D channel, & Log Amp channel connections | ||
| 16PIM-6c | Substitute Wet-pluggable (MCBH) connectors for Standard (XSG) connectors on SEACAT pump, A/D channel, & RS-232 channel connections | ||
| SBE 16plus-IM Dissolved Oxygen Sensor Options | |||
| 16PIM-7a | SBE 43 Dissolved Oxygen Sensor (Mooring Configuration), 7000 m (cable & mount included, requires option 16PIM-5b). |
See SBE 43
specification sheet for sensor description.Mooring Configuration differs from Profiling Configuration as follows (photo shows SBE 16plus integrated with SBE 43; 16plus-IM is similar):
SBE 43 connector type (standard or wet-pluggable) must match 16plus-IM
connector type. SBE 43 is plumbed in line
between conductivity sensor & pump; consequently, system requires
more powerful SBE 5T pump (16PIM-5b or -5d) instead of 5M pump (16PIM-5a
or -5c). |
|
| 16PIM-7b | SBE 43 Dissolved Oxygen Sensor (Mooring Configuration) with Wet-pluggable connector, 7000 m (cable & mount included, requires option 16PIM-5d & 16PIM-6_). | ||
| 16PIM-7c | SBE 43 Dissolved Oxygen Sensor (Mooring Configuration), 600 m plastic (cable & mount included, requires option 16PIM-5b). | ||
| 16PIM-7d | SBE 43 Dissolved Oxygen Sensor (Mooring Configuration) with Wet-pluggable connector, 600 m plastic (cable & mount included, requires option 16PIM-5d & 16PIM-6_). | ||
| SBE 16plus-IM Accessories | |||
| 801542 | AF24173 Anti-foulant Device (pair, bagged, labeled for shipping) (replaces PN 801347) |
Anti-foulant
devices fit into anti-foulant device cups at each end of
conductivity cell. Anti-foulant devices included with standard
shipment; these are spares.Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments. |
|
| 80291 | 9-cell series alkaline battery pack (solder connected) |
Batteries are easily accessed by unscrewing battery
end cap. 16plus-IM comes standard with 9 D cell alkaline
batteries (nominal 14 Ah), but can be powered with Electrochem
lithium batteries for more power intensive / longer deployments. Note: Sea-Bird does not supply Electrochem lithium batteries; you must purchase them elsewhere (see WGT's website for purchasing information). Shipping restrictions apply for Electrochem lithium batteries & assembled battery packs. |
|
| 801483 | Battery pack assembly kit for 80547 9 D 10.8v/42Ah Lithium pack with instructions, cells not included (DN 67143) | ||
| 801479 | Battery pack assembly kit for 80540 3 DD 10.8v/30Ah Lithium pack with instructions, cells not included (DN 67144) | ||
| 50323 | SBE 16plus-IM Spares Kit (Standard connectors) - Complete support kit containing spare connectors, dummy plugs, & other mechanical spares & maintenance items. | Order appropriate spares kit for connector type on 16plus-IM: | |
| 50324 | SBE 16plus-IM Spares Kit (Wet-pluggable connectors) - Complete support kit containing spare connectors, dummy plugs, & other mechanical spares & maintenance items. | ||
| various | Plumbing | For assorted sizes of Tygon tubing, see SBE 5M Configuration Details. | |
| For Surface Inductive Modem (SIM) and Inductive Cable Coupler (ICC), see separate listing. | |||
Product configuration options listing for all products
![]()
Last modified: 06 Apr 2007
Sea-Bird Home Phone: 425-643-9866 Fax: 425-643-9954 E-mail: seabird@seabird.com