Brochure/specifications
Manual
Reference Sheet
Note: We do not publish prices on the website. Please contact Sea-Bird (seabird@seabird.com
or 425-643-9866) for pricing.
| Part # | Description | Notes |
| 19plus | SEACATplus PROFILER Pumped Conductivity, Temperature, Depth Recorder - Includes SBE 5M submersible pump, 8 MB memory, 2.5 m data I/O cable (PN 801225), SEASOFT software, & complete documentation. Specify: housing, pressure sensor, & auxiliary channel selections. Configurations that include pumped SBE 43 or other pumped auxiliary sensors require SBE 5T; see option 19p-4. |
19plus is intended primarily as a profiling CTD, sampling at 4 Hz, but can also be used in moored mode to obtain long-term time series data. 19plus is powered by internal batteries, & records data in memory. In addition, in profiling mode, 19plus can be deployed:
For photos of standard shipment, click here. |
|
SBE 19plus Housing (depth rating) Selections -- MUST SELECT ONE |
||
| 19p-1a | 600 m plastic housing | Pump (SBE 5M standard or SBE 5T optional) is titanium, regardless of housing option, & is rated for 10,500 m. |
| 19p-1b | 7000 m titanium housing | |
| SBE 19plus Strain Gauge Pressure Sensor Selections -- MUST SELECT ONE | ||
| 19p-2a | 20 m strain gauge pressure sensor |
Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest
pressure rating gives you most flexibility in using 19plus, it is at expense of
accuracy & resolution. It is advantageous to use lowest range
pressure sensor compatible with your intended maximum operating
depth, because accuracy & resolution are proportional to
pressure sensor's full scale range. For example, comparing 2000 &
7000 m sensors --
|
| 19p-2b | 100 m strain gauge pressure sensor | |
| 19p-2c | 350 m strain gauge pressure sensor | |
| 19p-2h | 600 m strain gauge pressure sensor | |
| 19p-2d | 1000 m strain gauge pressure sensor | |
| 19p-2e | 2000 m strain gauge pressure sensor | |
| 19p-2f | 3500 m strain gauge pressure sensor | |
| 19p-2g | 7000 m strain gauge pressure sensor | |
| SBE 19plus Auxiliary Analog Channel Configuration Selections (for optional sensors) -- MUST SELECT ONE | ||
| 19p-3a | 4 differential A/D channels (0 - 5 volt input range) |
Auxiliary
sensors (dissolved oxygen, pH, fluorometer, transmissometer, etc.)
plug into bulkhead connectors on 19plus connector end cap.
Note: 19p-3a & -3b do not include auxiliary sensors, mounts, or interface cables.
|
| 19p-3b | 3 differential A/D channels, 1 log amp channel (for PAR) | |
| SBE 19plus Pump Option | ||
| 19p-4 | Substitute SBE 5T pump for SBE 5M pump |
Standard
SBE
5M pump is intended for providing pumped conductivity only, for
improved conductivity response over a non-pumped system. Larger, more powerful SBE
5T is
required if also planning to pump auxiliary sensors (such as
dissolved oxygen, etc.).SBE 5T (as well as 5M) pump is titanium, regardless of 19plus housing option, & is rated for 10,500 m. |
|
SBE 19plus Wet-Pluggable Connector Options |
||
| 19p-5a | Substitute all Wet-pluggable (MCBH) connectors for Standard (XSG) connectors when Option 19p-3a is specified (including pump and data I/O cable) |
Wet-pluggable connectors may be mated in wet
conditions. Their pins do not need to be dried before mating. By
design, water on connector pins is forced out as connector
is mated. However, they must not be mated or un-mated while
submerged. Wet-pluggable connectors have a non-conducting guide pin
to assist pin alignment & require less force to mate, making them
easier to mate reliably under dark or cold conditions, compared to
our standard (Impulse XSG/RMG) connectors. Like standard connectors,
wet-pluggables need proper lubrication & require care during use
to avoid trapping water in sockets. Both 19p-5 options include additional cost of wet-pluggable connectors on 19plus & pump, data I/O cable compatible with wet-pluggable data I/O connector, & pump cable with wet-pluggable connectors on both ends.
|
| 19p-5b | Substitute all Wet-pluggable (MCBH) connectors for Standard (XSG) connectors when Option 19p-3b is specified (including pump and data I/O cable) | |
| SBE 19plus Auxiliary Sensor and Integration Options | ||
| 19p-6a | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), 7000 m (cable & mount included, requires option 19p-4) |
General Information:
Sensor-Specific Information:
Moored Application Information:
|
| 19p-6b | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 7000 m (cable & mount included, requires option 19p-4 & 19p-5a or 5b) | |
| 19p-6c | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), 600 m plastic (cable & mount included, requires option 19p-4) | |
| 19p-6d | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 600 m plastic (cable & mount included, requires option 19p-4 & 19p-5a or 5b) | |
| 19p-7a | SBE 18 pH sensor for use in profiling mode only, 1200 m (cable & mount included) | |
| 19p-7b | SBE 18 pH sensor for use in profiling mode only, with Wet-pluggable connector, 1200 m (cable & mount included – Requires option 19p-5a or b) | |
| 19p-8a | SBE 27 pH/ORP sensor for use in profiling mode only, 1200 m (cable & mount included) | |
| 19p-8b | SBE 27 pH/ORP sensor for use in profiling mode only, with Wet-pluggable connector, 1200 m (cable & mount included – Requires option 19p-5a or b) | |
| YMOLD | Extra charge to substitute Y-cable to connect two (2) or more sensors to one (1) bulkhead connector | |
| 19p-9a | Underwater power/data interface module (PDIM) integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, & mounting hardware) |
SBE 36 CTD Deck Unit & PDIM provide surface power &
real-time data acquisition & control for 19plus, allowing
deployment with 10,000 m long single-conductor sea cables. SBE
36 is installed on ship, while PDIM is mounted on or near 19plus.
See SBE 36 description for more information on interface. SBE 33 Deck Unit is typically used to provide surface power & real-time data acquisition & control for 19plus & SBE 32 (32, 32C, or 32SC) Carousel Water Sampler or SBE 55 ECO Water Sampler. However, it can be used with PDIM instead of Carousel or ECO to provide same functionality as SBE 36 & PDIM. PDIM housing is anodized aluminum, & is rated to 6800 m. PDIM connector type (standard or wet-pluggable) must match 19plus connector type. 19p-9a & -9b do not include SBE 36 or 33 Deck Unit; order separately.
|
| 19p-9b | Underwater power/data interface module (PDIM) with Wet-pluggable connectors integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, & mounting hardware – Requires option 19p-5a or 5b) | |
| SBE 19plus Accessories | ||
| 801269 | Stainless-steel protective cage, 40 in. (101 cm) tall (SEACATplus) |
Many
users purchase optional cage to protect system from damage during
deployment. 19plus deployed with SBE
32 (full size)
Carousel Water Sampler requires cage, which is mounted
horizontally to bottom of Carousel frame.19plus deployed on SBE 32C (compact) or 32SC (subcompact) Carousel Water Sampler is mounted in bottle position on Carousel, & does not use cage. Note: This cage is for use with SBE 19plus, but not with older SEACAT (SBE 19). |
| 801511 | 9 NiMH cells in rechargeable drop-in pack (10.8V/8 Ah) |
19plus
comes standard with alkaline batteries, but can be powered with
rechargeable NiMH batteries instead. Batteries are easily accessed
by unscrewing battery end cap.
|
| 90504 | NiMH battery charger for 6, 9, or 12 cells / 8 Ah D-cell packs. Provides full recharge in 2 hours, includes AC power cord & battery charging cable | |
| 801641 | 9 Ni-Cad cells in drop-in rechargeable pack (10.8V/4.4 Ah) |
|
| 90226 | Ni-Cad battery charger (90/240 VAC) for 6/9/12 cells (16 hour charger) | |
| 50288 | SBE 19plus Moored Mode Conversion Kit -- anti-foulant holders & hardware for user conversion from profiling to moored mode configuration. AF24173 anti-foulant devices (PN 801542) are NOT included. Note: When installed on 19plus at time of order, T-C Duct & related parts normally installed on profilers are provided as a separate Profiling Conversion Kit, PN 50345 (order 801542 anti-foulant devices separately, or PN 50288.1 Kit with anti-foulant devices) | 19plus is intended primarily for use as profiling instrument, & does not come standard with anti-foulant device fittings. Conversion kit allows user to retrofit 19plus with anti-foulant device fittings for moored applications. Anti-foulant device fittings attach to each end of conductivity cell. See document 67114 for details. Only 1 conversion kit is needed per instrument; order replacement Anti-Foulant Devices as needed (see 19plus Spares below). |
| 20163 | USB to 232 Serial (DB-9P) Adapter, IOGear GUC232A (connects portable computers with USB adapters to RS-232 instruments) | Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68. |
| Underwater Cable for Hand-Hauled, Real-Time Profiling (see Application Note 59 for proper use and limitations) | ||
| 801150 | Load-bearing Data cable, Standard connector, w/ DB-9S, 30 m (100 ft) (DN 32284) |
These cables are for hand-hauling 19plus &
acquiring real-time data. Cables are not intended for static working
loads above 45 kg (100 lbs); working loads above 18 kg (40 lbs) may
be difficult to handle without winch. Minimum recommended cable bend
radius is 10 cm (4 in.) (e.g., 20 cm sheave block nominal diameter).
See Application Note 59:
A Load-Bearing Underwater Cable for Hand-Hauled, Real-Time Profiling. Select a cable with connector (standard XSG or wet-pluggable MCBH) to match your 19plus. |
| 801295 | Load-bearing Data cable, Standard connector, w/ DB-9S, 50 m (165 ft) (DN 32284) | |
| 801140 | Load-bearing Data cable, Standard connector, w/ DB-9S, 61 m (200 ft) (DN 32284) | |
| 801153 | Load-bearing Data cable, Standard connector, w/ DB-9S, 100 m (330 ft) (DN 32284) | |
| 801301 | Load-bearing Data cable, Standard connector, w/ DB-9S, 126 m (415 ft) (DN 32284) | |
| 801148 | Load-bearing Data cable, Standard connector, w/ DB-9S, 183 m (600 ft) (DN 32284) | |
| 801371 | Load-bearing Data cable, Wet-pluggable, w/ DB-9S, 30 m (100 ft) (DN 32643) | |
| 801372 | Load-bearing Data cable, Wet-pluggable, w/ DB-9S, 60 m (200 ft) (DN 32643) | |
| 801337 | Load-bearing Data cable, Wet-pluggable, w/ DB-9S, 100 m (330 ft) (DN 32643) | |
| 801338 | Load-bearing Data cable, Wet-pluggable, w/ DB-9S, 200 m (660 ft) (DN 32643) | |
| SBE 19plus Spares | ||
| 50276 | SBE 16plus/19plus Spares Kit (Standard connectors) - Complete support kit containing spare data I/O cable, connectors, dummy plugs, & other mechanical spares & maintenance items. | Order appropriate spares kit for connector type on 19plus: |
| 50301 | SBE 16plus/19plus Spares Kit (Wet-pluggable connectors) - Complete support kit containing spare data I/O cable, connectors, dummy plugs, & other mechanical spares & maintenance items. | |
| 50275 | SBE 19plus magnetic switch assembly |
|
| 41124 | Battery cover/contact plate, replaces 80076.1 |
Cover
plate for alkaline batteries. |
| 801225 | Data I/O cable, Standard connector (RMG-4FS) w/ DB-9S, 2.4 m (DN 32421) | These test cables are used for setting up system & uploading data from memory after recovery. Applicable cable is included with 19plus; these are spares. |
| 801374 | Data I/O cable, Wet-pluggable (MCIL-4FS) w/ DB-9S, 2.4 m (DN 32715) | |
| 801542 | AF24173 Anti-foulant Device (pair, bagged, labeled for shipping) (replaces PN 801347) |
Anti-foulant
devices are typically used when 19plus is deployed on a
mooring, instead of as a profiling CTD. Use of Anti-foulant devices
requires installation of PN 50288 SBE 19plus Moored Mode
Conversion Kit (see SBE 19plus Accessories above); anti-foulant
devices fit into anti-foulant device cups at each end of
conductivity cell.Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments. |
| 50087 | Cell filler/storage device | For cleaning conductivity cell after each use & storing instrument between uses. See document 67043 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells. |
| various | Plumbing spares | For air bleed valve and y-fitting, and assorted sizes of Tygon tubing, see SBE 5M Configuration Details. |
Product configuration options listing for all products
![]()
Last modified: 06 Apr 2007
Sea-Bird Home Phone: 425-643-9866 Fax: 425-643-9954 E-mail: seabird@seabird.com