Brochure/specifications
Manual
Note: We do not publish prices on the website. Please contact Sea-Bird (seabird@seabird.com
or 425-643-9866) for pricing.
| Part # | Description | Notes |
| 9plus | UNDERWATER UNIT for 911plus CTD - Includes modular Temperature & Conductivity sensors with TC Duct, SBE 5T submersible pump, redundant T & C input channels, 8 differential input, low pass-filtered A/D channels, water sampler modem channel, stainless steel guard cage, SEASOFT software, & complete documentation. Specify: housing/connector & pressure sensor range (depth limit) selections. | For photos of standard shipment,
click here.
9plus provides real-time data when
controlled with 11plus Deck Unit. Deck Unit provides power, decodes
data stream, passes data to computer, & allows user control of water sampler.
Autonomous Operation Notes: |
|
SBE 9plus Housing and Connector Selections -- MUST SELECT ONE |
||
| 9p-1a | Aluminum housing, 6800 m depth rating (Standard connectors) | 9plus is available for
maximum depths of 6800 m (aluminum housing for main housing & T & C sensors)
or 10,500 m (titanium housing for main housing & T & C sensors). SBE 5T pump
is titanium, regardless of housing option, & is rated for 10,500 m. These options include standard or wet-pluggable bulkhead connectors. Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to our standard (Impulse XSG/RMG) connectors. Like standard connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.
|
| 9p-1b | Aluminum housing, 6800 m depth rating with Wet-pluggable connectors on CTD, T&C sensors, pump, & related cables | |
| 9p-1c | Titanium housing, 10,500 m depth rating (Standard connectors) | |
| 9p-1d | Titanium housing, 10,500 m depth rating with Wet-pluggable connectors on CTD, T&C sensors, pump, & related cables | |
| SBE 9plus Pressure Sensor Range (Depth Limit) Selections -- MUST SELECT ONE | ||
| 9p-2a | 0 - 2000 psia (1400 m) pressure sensor |
Pressure sensor is installed in main housing
bottom end cap.
Unlike modular T & C sensors, pressure sensor is not
field-replaceable / swappable. While highest pressure rating gives
you most flexibility in using 9plus, it is at expense of
accuracy & resolution. It is advantageous to use lowest range
pressure sensor compatible with your intended maximum operating
depth, because accuracy & resolution are proportional to
pressure sensor's full scale range. For example, comparing 1400 &
4200 m sensors --
|
| 9p-2b | 0 - 3000 psia (2000 m) pressure sensor | |
| 9p-2c | 0 - 6000 psia (4200 m) pressure sensor | |
| 9p-2d | 0 - 10,000 psia (6800 m) pressure sensor | |
| 9p-2e | 0 - 15,000 psia (10,500 m) pressure sensor | |
| SBE 9plus Secondary Temperature and Conductivity Sensor Options | ||
| 9p-3a | Secondary T & C sensors, 6800 m, with TC Duct & Pump |
Secondary
(redundant) T & C sensors can be used to verify data from primary T & C
sensors, for applications requiring very high accuracy. Secondary sensors
come complete with TC Duct & secondary pump (& all associated plumbing), &
mount onto main housing bottom end cap like primary sensors. Secondary
sensors are available for maximum depths of 6800 m (aluminum housing on T &
C sensors) or 10,500 m (titanium housing on T & C sensors). Standard 9plus is
compatible with secondary T & C sensors; secondary sensors can be added to
system in field without any modification to 9plus electronics.Secondary sensor connector type (standard or wet-pluggable) must match 9plus connector type. |
| 9p-3b | Secondary T & C sensors, 6800 m, with TC Duct, Pump, with Wet-pluggable connectors (requires option 9p-1b) | |
| 9p-3c | Secondary T & C sensors, 10,500 m, with TC Duct & Pump | |
| 9p-3d | Secondary T & C sensors, 10,500 m, with TC Duct, Pump, with Wet-pluggable connectors (requires option 9p-1d) | |
|
SBE 9plus Command Telemetry Options |
||
| 9p-4a | DELETE for Credit -- 300 baud modem module for water sampler control | With standard water sampler modem in 9plus
& 11plus, system provides real-time control for SBE
32 or 32C
Carousel Water Sampler or G.O. 1016 water sampler. Water sampler modem not required:
|
| 9p-4b | Control module for GO 1015 water sampler, includes interface cables (requires water sampler modem) | With standard water sampler modem in 9plus & 11plus, & option 9p-4b in 9plus, system provides real-time control for G.O. 1015 Rosette water sampler. |
| 9p-4c | Optional RS-232 serial output interface, installed in place of 1015 interface. 9plus data output duplicates the output from the SBE 11plus deck unit, except that averaging and alignment must be done in post processing. This is a custom option for AUV integration applications. A PC running SEASAVE will be able to display and archive CTD data directly from the 9plus – no deck unit required. | This option is typically desired when an AUV / ROV is logging 9plus data. When 9p-4c is ordered, PCB for G.O. 1015 is replaced with PCB for RS-232 serial output. 9plus transmits serial data through 3-pin JT4 connector on 9plus top end cap at 19,200 baud, 8 data bits, no parity. Power can also be supplied to 9plus through JT4 connector. |
|
SBE 9plus Auxiliary Sensor Options |
||
| 9p-6a | SBE 43 Dissolved Oxygen sensor (Profiling Configuration), 7000 m (Standard connectors). Cable & mount included. |
General Information:
Sensor-Specific Information:
|
| 9p-6b | SBE 43 Dissolved Oxygen sensor (Profiling Configuration), 7000 m (Wet-pluggable connectors). Cable & mount included. (requires option 9p-1b or 1d) | |
| 9p-7a | SBE 18 pH sensor, 1200 m (Standard connectors). Cable & mount included. | |
| 9p-7b | SBE 18 pH sensor, 1200 m (Wet-pluggable connectors). Cable & mount included. (requires option 9p-1b or 1d) | |
| 9p-8a | SBE 27 pH/ORP sensor, 1200 m (Standard connectors). Cable & mount included. | |
| 9p-8b | SBE 27 pH/ORP sensor, 1200 m (Wet-pluggable connectors). Cable & mount included. (requires option 9p-1b or 1d) | |
| YMOLD | Extra charge to substitute Y-cable to connect two (2) or more sensors to one (1) bulkhead connector | |
| 9p-9a | Bottom Contact Switch module (Standard connector, cable & mount included) |
Weight is attached with heavy
line to switch. Switch closes when weight removed, setting bit in 9plus
data stream. This causes alarm to turn on in 11plus Deck Unit,
providing early warning that CTD is nearing ocean floor. Bottom contact
switch does not use one of 8 A/D channels, so system can accommodate switch in addition to 8 auxiliary sensors.Bottom contact switch connector type (standard or wet-pluggable) must match 9plus connector type. Note: In mid-February 2007, Sea-Bird began using a female bulkhead connector on the 9plus for the bottom contact switch, in place of the male bulkhead connector. This change was made to differentiate the bottom contact switch connector from the sea cable connector. See bottom end cap photo above; see Application Note 86 for details. |
| 9p-9b | Bottom Contact Switch module (Wet-pluggable connector, cable & mount included) (requires option 9p-1b or 1d) | |
| 9p-10 | Isolated power (on 1 A/D connector only), required for 3000 m Sea Tech fluorometer | |
| 9p-11a | Serial Data Uplink, 9600 unidirectional RS-232, with 9600 baud sensor communication interface (requires water sampler modem channel, limits cable length to 8,000 m, prevents GO 1015 interface, & makes 9plus incompatible with SBE 17plus SEARAM & other 911plus CTDs that do NOT have this option) |
300
baud modem for water sampler control (see note) is required to support serial data uplink. Serial
data is multiplexed into 9plus telemetry stream & de-multiplexed by
11plus, outputting to computer through standard 9600 Baud Uplink
connector. System supports use of serial data output instrument & water
sampler in same cast.If 9p-11b (19200 baud) selected, continuous transmission rate may not exceed 9600 baud (960 bytes/second). Therefore, serial data output instrument must transmit at 19200 baud in burst mode (transmissions separated by intervals with no data transmission, resulting in average rate of 960 bytes/second). When 9p-11a or 11b is ordered, 3-pin JT4 connector for G.O. 1015 on 9plus top end cap is replaced with 4-pin serial data connector. *Note: 300 baud modem in 9plus & 11plus has been standard since early 2005. For older instruments, it was optional. |
| 9p-11b | Serial Data Uplink, 9600 unidirectional RS-232, with 19200 baud sensor communication interface (requires water sampler modem channel, limits cable length to 8,000 m, prevents GO 1015 interface, & makes 9plus incompatible with SBE 17plus SEARAM & other 911plus CTDs that do NOT have this option) | |
|
SBE 9plus Wide Range Calibration Options |
||
| 9p-12a | Wide Range Calibration - Primary T & C | Standard calibration range
goes up to +32.5 °C & 6 S/m; more than 99% of oceanographic work is below
this temperature & conductivity. Our calibration equations & fits permit
extrapolations significantly beyond this range with only minor loss of
accuracy. Wide range calibration goes up to +43 °C & 9 S/m. Wide range calibrations require a 12-week lead time. |
| 9p-12b | Wide Range Calibration - Secondary T & C (requires option 9p-12a) | |
| SBE 9plus Spares/Accessories | ||
| 32000 | Technical Manual (spare), SBE 911plus CTD system | 32000 includes 9plus CTD manual & 11plus Deck Unit manual; 32000.5 includes 9plus CTD manual only. These manuals are customized for your application, & include instrument configuration, calibration sheets, & schematics specific to your instrument. Note that electronic version of customized manuals are available on CD-ROM that accompanies shipment; see links at top of page for generic manuals. |
| 32000.5 | Technical Manual (spare), SBE 9plus Underwater Unit (only) | |
| 50088 | SEASPARES (Aluminum), SBE 9Plus support kit containing spare sensor cables, connectors, hardware, o-rings, clamps, tubing, fittings, anodes, etc. | Order appropriate
SEASPARES kit for housing type and connector type on 9plus:
|
| 50139 | SEASPARES (Titanium), SBE 9Plus support kit containing spare sensor cables, connectors, hardware, O-rings, clamps, tubing, fittings, etc. | |
| 50321 | Wet-pluggable SEASPARES (Aluminum), SBE 9Plus support kit containing spare sensor cables, connectors, hardware, O-rings, clamps, tubing, fittings, anodes, etc. | |
| 50322 | Wet-pluggable SEASPARES (Titanium), SBE 9Plus support kit containing spare sensor cables, connectors, hardware, O-rings, clamps, tubing, fittings, etc. | |
| 17252 | 2-pin seacable extension, 76 cm (DN 30588) | Female end connects to JT1 on 9plus top end cap (connector type must match 9plus); male end connects to sea cable. Many users leave extension connected to 9plus, & make connection to sea cable at end of extension (instead of at end cap, which is crowded with a number of connectors & may be difficult to access). |
| 17120 | 2-pin seacable extension, 2 m (DN 30588) | |
| 171090 | 2-pin seacable extension, 3 m (DN 30588) | |
| 171743 | 2-pin seacable extension, Wet-pluggable, 2 m (DN 32763) | |
| 171744 | 2-pin seacable extension, Wet-pluggable, 3 m (DN 32763) | |
| 17198 | Interface cable, 9plus to 32, Standard connectors, 2 m (DN 30568) | Connects 9plus to SBE 32 or 32C Carousel Water Sampler. Connector type (standard or wet-pluggable) must match 9plus & SBE 32 or 32C connector type. Note that interface cable & mounting hardware are included with Carousel if Carousel is ordered with CTD integration kit for 9plus. |
| 171741 | Interface cable, 9plus to 32, Wet-pluggable, 2 m (DN 32758) | |
| 17086 | SBE 3 (Temperature) or SBE 4 (Conductivity) interface cable, 63 cm (DN 30566) | Spare cable to connect 9plus to SBE 3plus or 4C. Connector type (standard or wet-pluggable) must match 9plus & SBE 3plus or 4C connector type. |
| 171669 | SBE 3 (Temperature) or SBE 4 (Conductivity) interface cable, Wet-pluggable, 76 cm (DN 32671) | |
| 17133 | Pump cable RMG-2FS to RMG-2FS, 112 cm, for horizontal configuration with DO (DN 30565) | Spare cable to connect 9plus to SBE 5T pump. Connector type (standard or wet-pluggable) must match 9plus & SBE 5T connector type. |
| 171503 | Pump cable, Wet-pluggable MCIL-2FS to MCIL-2FS, 112 cm, for horizontal configuration with DO (DN 32499) | |
| 80593 | Sea cable interface assembly | Spare PCBs for 9plus. Contact Sea-Bird with serial number of your 9plus to verify correct part number for PCB. |
| 801017 | 9plus Modem Card | |
| 80585 | Control module for model 1015 water sampler | |
| 80589 | Analog interface card | |
| 80581 | Transmitter card | |
| 80621 | Logic card | |
| 80935 | Modulo 12P card (Substitute for PN 80640) | |
| 80609 | AP counter card | |
| 80590 | Control, store - A/D card | |
| 50087 | Cell filler/storage device | For cleaning conductivity cell after each use & storing instrument between uses. See document 67043 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells. |
| various | Plumbing spares | For air bleed valve and y-fitting, snap-on connector, and assorted sizes of Tygon tubing, see SBE 5M Configuration Details. |
Product configuration options listing for all products
![]()
Last modified: 06 Apr 2007