Field Service Bulletins

This page contains links to alerts on product problems that may cause injury to people, damage to equipment, or loss of data.

Field Service Bulletin Number & Date Product Brief Description
#11 -- December 2006 SBE 37-IMP, 37-SMP, 37-SIP When deployed in very turbid waters, pumped MicroCATs oriented with the intake/exhaust plumbing in an upright U-shape can become clogged with sediment; this results in poor flushing, causing poor quality data. Sea-Bird now recommends that the MicroCAT be oriented with its intake / exhaust in an inverted U-shape. A minor design modification allows trapped air to escape; a retrofit kit allows the customer to easily implement the change.
#10 -- December 2006 SBE 39 Retrofit kit provides better battery support (strong repetitive motions can cause the battery to vibrate; battery movement can crack PCB). Very few customers have had problems with battery vibration causing damage.
#9 -- November 2006 SEACAT -- SBE 16plus, 16plus-IM, 19plus, and 21 SEACATs store data incorrectly after a Flash Initialize command is sent, if logging is started before sending the Initialize Logging command. It is anticipated that very few customers will have a problem with this bug.
#8 -- December 2005 SBE 26plus SBE 26plus with firmware version 5.2, 6.0, and 6.0a require firmware upgrade to use a wave sample duration other than 0.25 seconds/sample.
#7 -- September 2005 SBE 39 SBE 39s with firmware version 2.0 and 2.0a require firmware upgrade to take full advantage of 4 MB memory.
#6 -- August 2004 SBE 9plus Modification required to prevent 9plus damage if 9plus used with alkaline-powered SBE 17plus SEARAM
#5 -- November 2003 SBE 41 / 41CP CTD Sensors for ARGO floats Handling precautions to prevent Electrostatic Discharge (ESD) damage
#4 -- August 2003 SBE 19plus
(with optional cage, shipped before August 1, 2003)
Retrofit kit strengthens the connection of the SBE 19plus to the cage (connection failure could lead to loss of the instrument)
#3 -- April 2001 SBE 37
(-IM, -SM, and -SI with Paine pressure sensor, full scale pressure < 1500 psi, and serial number < 1789)
Retrofit kit prevents intrusion of salt water into the pressure sensor cavity (which could lead to corrosion)
#2 -- March 1997 SBE 25 (shipped before March 1997) Modification at Sea-Bird required to prevent potential for sensor damage from transient over-voltage condition
#1 -- August 1997 Opto-Isolated Junction Boxes
(with external fuse holder, shipped before August 1997)
Product Recall -- A potentially dangerous condition may exist
     

For bugs that may prevent the equipment and/or software from functioning as expected (but that cannot cause injury or damage), go to the Known Bugs page.